GEMCO Series - S955 - Specifications

Measurement
Measurement Range 100mm to 4572mm (4” to 180”)
Accuracy +/-0.05% of FRO or 1.27mm whichever is greater
Non-linearity +/-0.01% of FRO or 0.71mm whichever is greater
Resolution .035mm
Repeatability +/- 0.01% of FRO or +/-.035mm whichever is greater
Hysteresis ±0.01% of FRO
Dead Band 38.1mm (1.50”) standard
Null Zone 76.2mm (3.00”) standard
Mechanical
Body Length  
Hex Base  
Thread  
LED Diagnostic Tri-Colour LED
Electrical Interface
Input Voltage 10-30 VDC
Current Draw 100mA Maximum
Connector 4 Pin 12mm Euro micro
Update Time

100=mm to ≤ 1270mm = 1ms

1271mm to ≤ 2540mm = 2ms

2541mm to ≤ 3810mm = 3ms

3811mm to ≤ 4572mm = 4ms

   
LED Diagnostic Tri-Colour LED
Green = Power is applied and magnet is present Red = Fault, magnet is in the Dead Zone or lost Yellow = Out of the active programmed range
Zero & Span Adjustability Factory set at Null & Dead Band locations, Field re-settable at any location within active stroke programmed range
Output V0 = 0-10 VDC
V1 = 10-0 VDC
V2 = -10 to 10 VDC
V3 = 10 to -10 VDC
V4 = 0 to 5 VDC
V5 = 5 to 0 VDC
V6 = -5 to 5 VDC
V7 = 5 to -5 VDC
C4 = 4 to 20Ma
C4 = 20 to 4mA
Environmental
Storage Temperature 40°C to 105°C (-40° to 221° F)
Operating Temperature
Head
Guide Tube
-40°C to 70°C (-40°C to 158°F)
Enclosure IP67, IP68 Optional
Vibration  
Shock  
Guide Tube Pressure  
Materials
Housing
Cover
Rod
Aluminium
 
 

 

Product and Technology News

Orbit® Gauge Software

Application Selector

Solartron Metrology