+/- 0.01% of FRO or +/-.035mm whichever is greater
Hysteresis
±0.01% of FRO
Dead Band
38.1mm (1.50”) standard
Null Zone
76.2mm (3.00”) standard
Mechanical
Body Length
Hex Base
Thread
LED
Diagnostic Tri-Colour LED
Electrical Interface
Input Voltage
10-30 VDC
Current Draw
100mA Maximum
Connector
4 Pin 12mm Euro micro
Update Time
100=mm to ≤ 1270mm = 1ms
1271mm to ≤ 2540mm = 2ms
2541mm to ≤ 3810mm = 3ms
3811mm to ≤ 4572mm = 4ms
LED
Diagnostic Tri-Colour LED
Green = Power is applied and magnet is present Red = Fault, magnet is in the Dead Zone or lost Yellow = Out of the active programmed range
Zero & Span Adjustability
Factory set at Null & Dead Band locations, Field re-settable at any location within active stroke programmed range
Output
V0 = 0-10 VDC
V1 = 10-0 VDC
V2 = -10 to 10 VDC
V3 = 10 to -10 VDC
V4 = 0 to 5 VDC
V5 = 5 to 0 VDC
V6 = -5 to 5 VDC
V7 = 5 to -5 VDC
C4 = 4 to 20Ma
C4 = 20 to 4mA