GP-3310T AGP3310-T1-D24(PFXGP3310TAD)

datasheet GP-3310T_EN.pdf

Display Type
TFT Color LCD
Display Size
5.7"
Resolution
640 x 480 pixels (VGA)
Dot pitch
W0.18 x H0.18 mm [W0.01 x H0.01 in.]
Effective Display Area
W115.2 X H86.4mm [W4.54 X H3.40in.]
Display Colors
65,536 Colors (No blink)/16,384 Colors (Blink)
Backlight
White LED (User nonreplaceable parts. Factory replacement required.)
Brightness Control
8 Levels (Adjusted with the touch panel)
Contrast Control
Not applicable
Backlight Service Life
50,000 hrs. or more (continuous operation at 25℃ before backlight brightness decreases to 50%)
Language Fonts
Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters), ANK: 158 (Korean fonts, Simplified Chinese and Traditional Chinese fonts are downloadable.
Character Sizes
Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts
Font Sizes
Standard font: Width can be expanded up to 8 times., Height can be expanded up to 8 times.*1
8 x 16 dots
80 char. x 30 rows
16 x 16 dots
40 char. x 30 rows
32 x 32 dots
20 char. x 15 rows
8 x 8 dots
80 char. x 60 rows
Program Area
FLASH EPROM 132 KB
Number of Step
Equivalent to 15,000 steps*2
Variable Area
SRAM 64 KB (uses lithium battery)*3
Application Memory
FLASH EPROM 8 MB*4
Data Backup
SRAM 320KB (uses lithium battery)*5
Clock Accuracy
±65 sec./month (deviation at room temperature and power is OFF)*6
Touch Panel Type
Resistive Film (analog)
Touch Panel Resolution
1,024 X 1,024
Touch Panel Service Life
1,000,000 times or more
Serial (COM1)
RS-232C/422/485, Asynchronous Transmission, Data Length: 7 or 8 bit, Parity: none, Even or Odd, Stop Bit: 1 or 2 bit, Data Transmission Speed: 2,400 bps to 115.2 kbps, Connector: D-Sub9 (plug)
Serial (COM2)
RS-422/485, Asynchronous Transmission, Data Length: 7 or 8 bit, Parity: none, Even or Odd, Stop Bit: 1 or 2 bit, Data Transmission Speed: 2,400 bps to 115.2 kbps, 187.5kbps (MPI), Connector: D-Sub9 (socket)
Ethernet (LAN)
IEEE802.3i/IEEE802.3u, 10BASE-T/100BASE-TX, Connector: Modular jack (RJ-45) x 1
Expansion Unit 1
Communication Expansion Unit X 1
USB (TYPE-A)
Conforms to USB1.1 (TYPE-A) x 2, Power Supply Voltage: DC 5 V ±5 %, Output Current: 500 mA or less, Communication Distance: 5 m or less
CF Card
Compact Flash CF Card Slot (TYPE-II) X 1
Sound Output
Speaker Output, 70 mW (Rated Load: 8 Ω, Frequency: 1 kHz), Connector: 2-piece terminal block (AUX) x 1

1Other font sizes can be set up with the Editor software.

2Up to 60,000 steps can be converted in software. However, this reduces internal memory capacity (for screen data) by 1 MB.

3A Lithium battery's lifetime is:
10 years when the battery's ambient temperature is 40 oC or less.
4.1 years when the battery's ambient temperature is 50 oC or less.
1.5 years when the battery's ambient temperature is 60 oC or less.
When used for back up: Approximately 100 days, with a fully charged battery.
Approximately 6 days, with a half-charged battery.

4Capacity available for user application.

5A Lithium battery's lifetime is:
10 years when the battery's ambient temperature is 40 oC or less.
4.1 years when the battery's ambient temperature is 50 oC or less.
1.5 years when the battery's ambient temperature is 60 oC or less.
When used for back up: Approximately 100 days, with a fully charged battery.
Approximately 6 days, with a half-charged battery.

6Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec./month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.

General Specifications

International Safety Standards
Rated Input Voltage
DC 24V
Input Voltage Limits
DC 19.2 to 28.8V
Allowable Voltage Drop
5 ms or less
Power Consumption
26 W or less
In-Rush Current
30 A or less
Voltage Endurance
AC1,000V 20mA for 1 minute, (between charging and FG terminals)
Insulation Resistance
DC500V 10MΩ (min.), (between charging and FG terminals)
Surrounding Air Temperature
0 to 50 °C (32 to 122 °F)
Storage Temperature
-20 to 60 °C (-4 to 140 °F)
Ambient Humidity
10 to 90% RH (Wet bulb temperature: 39℃ max. - no condensation.)
Storage Humidity
10 to 90% RH (Wet bulb temperature: 39℃ max. - no condensation.)
Dust
0.1mg/m³ and below (non-conductive levels)
Pollution Degree
For use in Pollution Degree 2 environment
Atmosphere
Free of corrosive gases
Air Pressure (altitude range)
800 to 1,114 hPa (2,000 m [6,561ft.] above sea level or less)
Vibration Resistance
IEC/EN61131-2 compliant, 5 to 9Hz Single amplitude 3.5mm [0.14in.], 9 to 150Hz Fixed acceleration: 9.8m/s², X,Y,Z directions for 10 cycles (100 minutes)
Concussion Resistance
IEC/EN61131-2 compliant, 147 m/s², X, Y, Z directions for 3 times
Noise Immunity
Noise Voltage: 1,000Vp-p, Pulse Duration: 1µs, Rise Time: 1ns, (via noise simulator)
Electrostatic Discharge Immunity
Contact Discarge Method: 6kV (IEC/EN61000-4-2 Level 3)
Grounding
Functional grounding: Grounding resistance of 100Ω, 2mm² or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
Structure
Equivalent to IP65f NEMA #250 TYPE 4X/13 (Front surface of embedded panel)*7
Installation Configuration
Embedded panel
Cooling Method
Natural air circulation
Weight Approx.
1 kg [2.2 lb] or less (display unit only)
External Dimensions
W167.5 X H135 X D59.5mm, [W6.59 X H5.31 X D2.34in.]
Panel Cut Dimensions
W156.0 X H123.5mm [W6.14 X H4.86in.], Panel thickness area: 1.6 to 5.0mm [0.06 to 0.20in.]*8

7The front face of the GP unit, installed in a solid panel, has been tested using, conditions equivalent to the standards shown in the specification. Even though the, GP unit's level of resistance is equivalent to these standards, oils that should have, no effect on the GP can possibly harm the unit. This can occur in areas where either, vaporized oils are present, or where low viscosity cutting oils are allowed to adhere, to the unit for long periods of time. If the GP's front face protection sheet becomes, peeled off, these conditions can lead to the ingress of oil into the GP and separate, protection measures are suggested., Also, if non-approved oils are present, it may cause deformation or corrosion of the, front panel’s plastic cover. Therefore, prior to installing the GP be sure to confirm the, type of conditions that will be present in the GP's operating environment., If the installation gasket is used for a long period of time, or if the unit and its gasket, are removed from the panel, the original level of the protection cannot be guaranteed., To maintain the original protection level, be sure to replace the installation gasket, regularly.

8Regarding dimensional tolerance, everything +1/-0mm [+0.04/-0in.] and R in angle are below R3 [R0.12in.].

 

External Dimensions / Interfaces / Panel Cut-out / Cable Attached Dimensions