Futek LSB200 with Pavone Sistemi DAT1400

 

DAT1400 - THEROTICAL CALIBRATION

 

DAT1400 - CALIBRATION WITH A PROOF WEIGHT

 

 

DAT 1400 ETHERCAT

Weighing Instrumentation Weight Transmitters

DOWNLOADS

  • Acquisition frequency signal A / DC up to 1000 Hz
  • DATALOGGER function (optional)
  • Capacitive keyboard
  • Bus contemporary Availability of Field and Analog Output
  • Removable screw terminal blocks
  • Mounting Type: DINRAIL & front panels (optional)
  • Future Options: - Two weighing channels indipendenti
  •                              - Analog voltage input or current
  •                              - Connection (RS485 and power supply) to I-BOX external

TECHNICAL DAT 1400 ETHERCAT

transducers Power:

5 Vdc (max 8 350-Ohm load cells in all)
Measuring range: ÷ -3.9 +3.9 mV / V
Input sensitivity: 00:02 MicroV / div
Linearity: <0.01% FS
Thermal drift: <0.001% FS / ° C
Display: 6 digits, red 7-segment LED, height 14mm
A / D converter: 24-bit
Internal resolution: > 16,000,000 points
Signal Acquisition frequency: 12 to 1000 Hz
Viewable resolution: 999,999 displayable divisions on net weight
Divisions value (selectable): x1, x2, x5, x10, x20, x50
Set Decimal: 0.0; 0:00; 0.000; 0.0000
Filter: Selectable 0.5 ÷ 1000 Hz
Keyboard: 4 capacitive buttons
Power tool: 12-24 Vdc ± 15% - absorbed power 5 W
Operating temperature: -10 / + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 / + 70 ° C
Logic outputs: 2 optoisolated; MAX 24 Vdc / 100mA cad
Logic inputs: 2 optoisolated PNP at 24 VDC (external power supply)
Serial Ports: 1 USB device + 1 + 1 RS232C RS485 / Fieldbus; ASCII protocol or Modbus RTU
Peak Hold function: for dynamic measurements
Optional analog output: optoisolated 16-Bit Voltage: 0 ÷ 5/10 V (R min10 K Ohm), Current: 0/4 ÷ 20 mA (R max 300 Ohm).
Linearity analogue output: <0.02% FS
Thermal analog output drift: 0.001% FS / ° C
Microcontroller: ARM Cortex M0 + 32-bit, 256KB Flash reprogrammable on-board USB
Data storage: 64 Kbytes expandable up to 1024 Kbytes
Regulatory Compliance: EN61000-6-2, EN61000-6-3 EMC; EN61010-1 for Electrical Safety
Electric connections: Removable screw terminal blocks 5 mm pitch
 
 

 

Product and Technology News

Correct installation of a weighing system

Product Selector

Pavone

Application Selector

Pavone

Download Catalogue