Catalog Download              
 

Sounding Bob Type Level Meter KSL Series

 
Sounding bob type level meter has a robust housing and performs an excellent durability under severe ambient conditions. It is applicable to various processes.
 

Features

 
  • With a simple mechanical detection system, it provides stable indications regardless of material in the tank and ambient conditions
  • Internal CPU enables direct pulse/analog output from the sensing unit.(KSL-T8, KSL-MT)
  • A trouble alarm contact available as standard. (KSL-T8, KSL-MT)
  • Many different check modes, including internal CPU self check mode are available
  • No external space for timer is needed as sensing parts contains auto measuing timer inside
 

Operating Principles

When a start signal is input, the motor is activated and the measuring tape is winded off to lower the weight. Accordingly, pulses are transmitted at regular intervals. Once the weight touches the surface of the material in the tank, the motor stops and the measurement value on the level meter is output. Then, the motor winds up the measuring tape to return to the original position.

Specifications

 
Specification
/Model
KSL-T8 KSL-T2
Power Voltage  100VAC or 200VAC,
 Single-phase 50/60Hz
 100VAC or 200VAC,
 Single-phase 50/60Hz
Consumption  Max.150VA  Max.150VA
Allowable Temperature  ambient : -10℃~+50℃
 (No freezing/condensation)
 Inside tank : -10℃~+80℃
 (No freezing/condensation)
 ambient : -10℃~+50℃
 (No freezing/condensation)
 Inside tank : -10℃~+80℃
 (No freezing/condensation)
Measuring Span  Standard 20m
 (40m Option)
 Standard 20m
 (40m Option)
Measuring Method  Pulse Counting  Pulse Counting
Measuring Unit  1 pulse/10cm,
 or 1 pulse/1cm
  1 pulse/10cm
Measuring Accuracy  ±10cm / ±1cm  ±10cm
Motor  Single-phase, Reversible,
 Output 40W
 30 minutes rating, with brake
 Single-phase, Reversible,
 Output 40W
 30 minutes rating, with brake
Body material  AC  SPCC
Mounting Method  JIS 5K 125A  JIS 10K 100A
Enclosure Rating  IP-67  Equivalent to IP-33
Output Signal  Current signal
  DC4~20mA(indicate remains)
  DC20~4mA(indicate vacated
           portion)
  (User can set up either one)
 Pulse contact signal
  1 pulse / 1cm
 (No-volt signal)
  1pulse / 10cm
  (User can set up either one)
 Possible to control 4-20mA output by combining an optional control unit and P / I converter.
Output Contact  Reset Contact/
  for Remote Indication Counter,
  ON at the time of reset
 Failure Alarm Contact/
  Flickers when the measuring
  tape is cut off.
  The contact is closed when
  the weight is buried.
 Possible to control both upper and lower output by combining an optional control unit and P / I converter.
 

Product Lineup

 
KSL-T8
KSL-T8
CPU Built-in Type (Tape)
KSL-MT
KSL-MT
CPU Built-in Compact Type (Tape)
KSL-T2
KSL-T2
Standard Type (Tape)
KSL-W2B
KSL-W2B
Standard Compact Type (Wire)
 
 

 

Product and Technology News

Capacitance Type Level Sensor Keyword

Product Selector

Kansai

Download Catalogue