pdf_16x16 Tracker 200 Series
pdf_16x16 Tracker 220
pdf_16x16 Tracker 220 Manual
zip Config Software
 
Tracker 220
 
A Range of High Accuracy Universal Input Digital Panel Meters for Temperature and Process Measurement.
You can find out more about the applications for the Tracker 220, for example as a digital temperature gauge, by visiting our applications section.You can download related documentation from the area to the left or contact us without obligation to discuss your requirements further.
 
Key Features:
Universal Input
Analogue Output
Digital Status Inputs
Transmitter & Transducer Supplies
4 Alarm Set-points
Wide Ranging Power Input
IP65 Front Panel
Standard 1/8 DIN Size
Red or Green LED Display
Programmable Function Buttons
Maths Functions
Serial Communications
 
You can connect any of the Tracker 220 series of digital panel meters to most process sensors including thermocouples, RTDs, 20mA, 100mV and 10VDC signals. All twenty of the thermosensor ranges have built-in linearisation. Automatic or external cold junction compensation and upscale or downscale sensor break detection for thermocouples can be selected by the user. The panel meter display can display temperatures in °C, °F or Kelvin (Absolute), with the decimal point position being user-adjustable to give the required measurement resolution. Process inputs can be scaled to any engineering units and can be linear, mapped to one of the thermosensor linearisation curves or be user linearised using the 24-point user linearisation feature.
 
All Tracker 220 digital panel meters are fitted with a electrically isolated 24 volt DC output to power a single 20mA 2-wire transmitter. In addition, the Tracker 221 and 222 panel meters have a 10V regulated supply and the Tracker 223 and 224 are fitted with a programmable 0-12 volt DC regulated output to power strain gauge-type sensors including load cells.
 
The Tracker 223 and 224 digital panel meters are fitted with an electrically isolated analogue output which cab be configured as 0-10 volt, 0-20mA or 4-20mA and scaled over any portion of the display range. For example, it's possible to retransmit a type K thermocouple as a linear 4-20mA signal equivalent to 0-500°C to a chart recorder or data logger. The analogue output is linear to temperature (display value). The analogue output can transmit the measured value (PV) or the maximum, minimum or the averaged value and has its own damping filter for noisy or fast moving signals. Alternatively it's possible to control the analogue output of the panel meter via the serial communication interface.
 
Some applications require a special linearisation curve to be defined by the user. A typical example is tank contents measurement where you can measure the level of a liquid but this is not linear to volume (e.g. litres) due to the shape of the tank. User linearisation allows you to define up to 24 calibration points which the signal value can be entered manually or, for greater accuracy, read directly from the sensor output.
 
Each of the Tracker 220 series of panel meters has 4 software alarms which can be configured for alarm type (High/Low/Deviation), setpoint, on/off delay times and on/off hysteresis values. Alarms can be individually set to be latching or non-latching and to flash a message on the front panel display when in an alarm state. Any of the 4 software alarms can operate a relay on Tracker 222 and 224 models. In addition, a special AND function allows a relay to switch only if 2 or more alarm conditions are active. You can set the relays to be energised or de-energised in the alarm condition.
 
Full setup is available using the front panel buttons to step through a simple password protected menu. You can make some functions, such as alarm setpoints, directly available to an operator. Alternatively, we can supply the panel meters without front panel buttons.
 
Two of the front panel buttons can be user programmed to provide one or more special functions such as:
Zero
Acknowledge - Reset Latched alarms
Reset Max Min Memory
Display Maximum PV/ Minimum PV/ Averaged PV/ All display segments (Lamp test)
 
Two status inputs are available allowing special functions to be switched remotley by volt free contacts or open collector TTL outputs. The functions available are:
Zero
Acknowledge - Reset Latched alarms
Alarm Disable
Display Maximum PV/ Minimum PV/ Averaged PV/ All display segments (Lamp test)
Reset Max Min Memory
Key Lock - Disables front panel keys
Analogue output hold
Display Hold
 
All T220 series panel meters have a RS485 serial interface. All measured values and setup parameters are accessible. Four communication protocols are available including MODBUS RTU and Datatrack's ASCII based protocol which has been easy to implement. The display, analogue output and relay outputs can all be controlled via the serial interface.
 
Wide-ranging 90-265V AC input allows world-wide installation. Low voltage 12-32 VAC/DC input version is also available.
The flat recessed display, together with high brightness red or green LEDs ensure maximum visibility of the digital panel meter, even in difficult ambient lighting conditions.
 

 

                    


 
 