Unidrive SP Free Standing - High power, ready-to-run drive cabinets

 

125 hp – 2,450 hp (90 kW – 1.6 MW)

230 V | 460 V | 575 V | 690 V

Unidrive SP Free Standing drives are fully engineered and tested drive cabinets for AC input and AC motor output configurations. The entire enclosure is certified to comply with international standards such as CE and UL. Proven design and international approvals free your engineering resources to focus on your application.

 
Features Specifications Options Software Downloads

Ratings

   

 

NORMAL DUTY [3]

HEAVY DUTY [3]

 

COMPACT WIDTH (mm)

ORDER 
CODE

MAX 
CONT. CURRENT (A)

TYPICAL MOTOR OUTPUT 
@ 400V (kW)

TYPICAL MOTOR OUTPUT
@ 460V (hp)

MAX 
CONT. CURRENT (A)

TYPICAL MOTOR OUTPUT 
@ 400V (kW)

TYPICAL MOTOR OUTPUT 
@ 460V(hp)

DRIVE ONLY

WITH SWITCH
DIS -
CONNECTOR

380-480Vac +/-10-%

400

400

SP64x1

205

110

150

180

90

150

SP64x2

236

132

200

210

110

150

SP74x1

290

160

250

238

132

200

SP74x2[4]


350


200


250


290


160


250

800

SP84x1

389

225

300

335

185

250

SP84x2

450

250

400

389

225

300

SP84x3

545

315

450

450

250

350

SP84x4

620

355

500

545

315

400

800

1200

SP94x0

690

400

600

593

315

500

SP94x1

690

400

600

620

355

500

SP94x3

900

500

800

790

450

700

SP94x4

1010

560

900

900

500

800

SP94x5

1164

675

1000

1010

560

900

1200

Not Available

SP94x5
+ 1 x SP94x5 
Ext,

1746

960

1500

1515

830

1250

1600

SP94x5
+ 2 x SP94x5 
Ext.

2328

1280

2000

2020

1110

1750

2000

SP94x5
+ 3 x SP94x5
Ext.

2910

1600

2500

2525

1380

2150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

Ratings shown are for IP21 at 40°C ambient or IP23 at 30°C ambient, 3kHz switching frequency and 1000m altitude.Ratings shown are for IP21 (NEMA 1) at 40°C ambient or IP23 at 30°C ambient, 3kHz switching frequency and 1000m (3,300ft) altitude.

  

 

 

 

 

 

NORMAL DUTY [3]

HEAVY DUTY [3]

 

COMPACT WIDTH (mm)

ORDER 
CODE

MAX 
CONT.
CURRENT (A)

TYPICAL MOTOR OUTPUT
@ 690V (kW)

TYPICAL
MOTOR OUTPUT 
@ 575V (hp)

MAX
CONT. CURRENT (A)

TYPICAL MOTOR OUTPUT 
@ 690V (kW)

TYPICAL MOTOR OUTPUT
@ 575V (hp)

DRIVE
ONLY

WITH SWITCH
DIS -
CONNECTOR

500-690Vac +/-10-%

400

400

SP66x1

125

110

125

100

90

100

SP66x2

144

132

150

125

110

125

SP76x1

168

160

150

144

132

150

SP76x2

192

185

200

168

160

150

800

SP86x1

231

200

250

186

185

200

SP86x2

266

225

300

231

200

250

SP86x3

311

315

350

266

250

300

SP86x4

355

355

400

311

315

350

800

1200

SP96x0

403

400

450

350

315

400

SP96x1

400

400

450

347

355

400

SP96x3

533

500

600

466

450

500

SP96x4

616

560

700

533

500

600

SP96x5

711

630

800

622

560

700

1200

Not Available

SP96x5
+ 1 x SP96x5 Ext.

1067

960

1150

933

830

1000

1600

SP96x5
+ 2 x SP96x5 Ext.

1422

1280

1550

1244

1120

1350

2000

SP96x5
+ 3 x SP96x5 Ext.

1778

1600

1950

1555

1380

1700

Ratings shown are for IP21 (NEMA 1) at 40°C ambient or IP23 at 30°C ambient, 3kHz switching frequency and 1000m (3,300ft) altitude.

 

 

Normal Duty Suitable for most applications, current overload of 110% for 165 seconds is available. Where motor rated current is less than the drive rated continuous current, higher overloads are achieved.
Heavy Duty Suitable for demanding applications, current overload of up to 150% for 60 seconds

 

Environmental Safety and Electrical Conformance 

 

Humidity 95% maximum (non condensing) at 40°C

Altitude: 0 to 3000m, derate 1% per 100m between 1000m and 3000m

Vibration: Drive Modules tested in accordance with IEC 60068-2-34

Mechanical Shock Tested: Drive Modules in accordance with IEC 60068-2-27

Storage temperature: -40°C to 50°C

Electromagnetic Immunity complies with EN 61800-3 and EN 61000-6-2

With on board EMC filter, complies with EN 61800-3 (2nd environment)

EN61000-6-4 with optional EMC filter (contact the supplier of your drive)

IEC 60146-1-1 General requirements

IEC 61800-5-1 Safety of Power Drive Systems

IEC 61131-2 I/O

EN 60529 Ingress protection

Safe Torque Off (Secure Disable) meets EN 954-1-cat3

UL508C (except drives with switch disconnector and IP23 drives)

CSA C22.2 no 14-05

IP21 (NEMA 1) cabinet design, optional IP23 (IP23 option not UL approved)

 

Dimensions and weights


 

Further information

 

Click here to download the Unidrive SP Free Standing brochure

 
 

 

Product and Technology News

500 kW High Power Drive

Application Selector

Control Techniques

Download Catalogue