Control Techniques’ Quantum MP is a packaged Mentor MP high performance DC drive providing reliability, power, and control to increase productivity for both new machines and applications in which DC motors are already installed.
The Quantum MP package includes the drive, fusing, power switching and 115Vac interface making it the ideal choice for rapid retrofits with regenerative and non-regenerative modules available to suit your application.
The Quantum MP saves engineering time and panel space making it ideal for North American customers.
High-speed semiconductor fusing for reliable circuit protection
115 Vac control interface to coordinate signals and commands to the drive
DC loop contactor with DB pole disconnects the Quantum MP drive from the motor armature when the stop command is given or in the event of a power failure
DC output fuse on all regen models helps avoid nuisance trips
Regenerative and non-regenerative modules available to best match application needs
Multiple fieldbus options including EtherNet/IP, Modbus TCP, PROFIBUS DP, and DeviceNet are used to integrate Quantum MP drives into automation systems
Enclosure IP00
Environment
Ambient operating temperature: 32 ° to 131 °F (0 ° to 55 °C )
Derate current 1.5% per °C from 104 ° to 131 °F (40 ° to 55 °C )
Cooling method QMP25-QMP45 natural convection
QMP75 and larger forced convection
Humidity 90 % relative humidity at 122 °F (50 °C)
Storage temperature: -40 ° to 131 °F (-40 ° to 55 °C )
Altitude: 0 to 9,842 ft (0 to 3,000 m), derate 1 % per 380 ft (100 m) between 3,280 ft (1,000 m) and 9,842 ft ( 3,000 m)
AC supply requirements
Supply voltage 208 to 480VAC ±10 %
Frequency 48 to 65 Hz
Supply fault current 100 kA
Drive efficiency 99 %
Armature voltage (max.) non-regen drives — 1.35 X input VAC; regen drives — 1.15 X input VAC
Field voltage (max.) 0.9 X input VAC with 1-phase input
Control
Analog input resolution: 16-bit plus sign, 250 μs (Qty 1), 10-bit plus sign, 250 μs (Qty 2)
Speed loop: 250 μs loop update
Current loop: 35 μs current sampling time
Feedback methods
Encoder (resolution 0.01 %)
DC tachometer (resolution 0.1 %); AC tachometer (resolution 1 %) (300 V max.)
Armature Voltage (resolution 5 % )
Optional additional incremental and absolute encoders (Qty 2)
Field control current regulated with flux control
QMP25-QMP 8 A
QMP350-QMP700 20 A
Optional FXMP25 25 A
Serial communications: 2- or 4-wire RS422 or RS485, optically-isolated
Protocol: ANSI x 3.28-2.54-A4 or Modbus RTU
Baud rate: 300 to 115,200
Protection & diagnostics
Control: Galvanic electrical isolation, 24 Vdc power supply