GP-4106G GP4106G1D(PFXGP4106G1D)

datasheet_GP4106G1D_EN.pdf

Functional Specifications

Display Type
STN Monochrome LCD
Display Size
3.4"
Resolution
200 x 80 pixels
Dot pitch
W0.4 x H0.4 mm [W0.02 x H0.02 in.]
Effective Display Area
79.985 x 31.985 mm
Display Colors
Monochrome Green/Red/Orange (16 Levels)
Backlight
Green/Red LED (User nonreplaceable parts. Factory replacement required.)*1
Brightness Control
16 Levels (Adjusted with the touch panel)
Contrast Control
8 Levels (Adjusted with the touch panel)
Backlight Service Life
Green: 50,000 hrs. or more, Red 10,000 hrs. or more (each in continuous operation at 25℃ before backlight brightness decreases to 50%)
Language Fonts
Japanese, ASCII, Chinese (Simplified), Chinese (Traditional), Korean, Cyrillic, Thai*2
Character Sizes
Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 80 pixel fonts, Image font: 8 to 72 pixel fonts
Font Sizes
Standard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times.*3
8 x 16 dots
25 char. x 5 rows
16 x 16 dots
12 char. x 5 rows
32 x 32 dots
6 char. x 2 rows
Application Memory
FLASH EPROM 2.2 MB*4
Data Backup
128KB*5
Clock Accuracy
Uses the clock of an external device*6
Touch Panel Type
Resistive Film (analog)
Touch Panel Resolution
1,024 x 1,024
Touch Panel Service Life
1,000,000 times or more
Serial (COM1)
RS-422/485, Asynchronous Transmission, Data Length: 7 or 8 bit, Parity: none, Odd or Even, Stop Bit: 1 or 2 bit, Data Transmission Speed: 2,400 bps to 115.2 kbps, Connector: 2-piece terminal block 9 pin
USB (TYPE-A)
Conforms to USB2.0 (Type-A) x 1, Power Supply Voltage: DC 5 V ±5 %, Communication Distance: 5 m or less*7
USB (mini-B)
Conforms to USB2.0 (mini-B) x 1, Communication Distance: 5 m or less

1The backlight burnout detection function is not supported.

2Please refer to the GP-Pro EX reference manual for details on font types and character codes.

3Other font sizes can be set up with the Editor software.

4Capacity available for user application.

5Application memory can provide 128KB for Data Backup. For further information, please refer to the GP-Pro EX reference manual.

6Set up the “Clock Updates“ feature with the Editor software. Please refer to the GP-Pro EX reference manual “Common” - “Clock Update Settings” for details.

7If connecting a bar code reader to the GP, be sure to supply power from an external source (such as a self-powered hub). If connecting a bar code reader to the GP, be sure to supply power from an external source (such as a self-powered hub). If you supply

General Specifications

International Safety Standards
Rated Input Voltage
DC 24V
Input Voltage Limits
DC 19.2 to 28.8V
Allowable Voltage Drop
3 ms or less
Power Consumption
3 W or less
In-Rush Current
30 A or less
Voltage Endurance
AC 1,000 V, 20 mA for 1 min (between charging and FG terminals)
Insulation Resistance
DC 500 V, 10 MΩ or more (between charging and FG terminals)
Surrounding Air Temperature
0 to 50 °C (32 to 122 °F)*8
Storage Temperature
-20 to 60 °C (-4 to 140 °F)
Ambient Humidity
10 to 90 % RH (Wet bulb temperature: 39 ℃ or less - no condensation.)
Storage Humidity
10 to 90 % RH (Wet bulb temperature: 39 ℃ or less - no condensation.)
Dust
0.1 mg/m³ or less (non-conductive levels)
Pollution Degree
For use in Pollution Degree 2 environment
Atmosphere
Free of corrosive gases
Air Pressure (altitude range)
800 to 1,114 hPa (2,000 m [6,561ft.] above sea level or less)
Vibration Resistance
IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration: 9.8 m/s², X, Y, Z directions for 10 cycles (100 min)
Concussion Resistance
IEC/EN61131-2 compliant, 147 m/s², X, Y, Z directions for 3 times
Noise Immunity
Noise Voltage: 1,000 Vp-p, Pulse Duration: 1 µs, Rise Time: 1 ns, (via noise simulator)
Noise Immunity (Fast Transient Burst Noise)
Power Line: 2 kV (IEC/EN61000-4-4), COM Port: 1 kV (IEC/EN61000-4-4)
Electrostatic Discharge Immunity
Contact Discharge Method: 6 kV/Air Discharge Method: 8 kV (IEC/EN61000-4-2 Level 3)
Grounding
Functional grounding: Grounding resistance of 100Ω, 2mm² or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
Structure
IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)*9
Installation Configuration
Embedded panel
Cooling Method
Natural air circulation
Weight Approx.
0.2 kg [0.4 lb] or less (display unit only)
External Dimensions
W116.5 x H77.5 x D28 mm [W4.59 x H3.05 x D1.1 in.]
Panel Cut Dimensions
W105 x H66 mm [W6.14 x H4.86 in.], Panel thickness area: 1 to 5 mm [0.04 to 0.2 in.]*10

8When using in an environment where the temperature becomes or exceeds 40 ℃ for an extended period of time, the screen contrast level may decrease from its original level of brightness.

9The front face of the GP unit, installed in a solid panel, has been tested using, conditions equivalent to the standards shown in the specification. Even though the, GP unit's level of resistance is equivalent to these standards, oils that should have, no

10Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if panel thickness is within recommend range for “Panel Cut Dimensions”, the panel could warp, depending on panel’s material, size, and insta

 

External Dimensions / Interfaces / Panel Cut-out