• GP-4501T 

     

    PFXGP4501TMD

     

    Datasheet

     

    Functional Specifications

    Display Type
    TFT Color LCD
    Display Size
    10.4"
    Resolution
    640 x 480 pixels (VGA)
    Effective Display Area
    W211.2 x H158.4 mm [W8.31 x H6.24 in.]
    Display Colors
    65,536 Colors (No blink)/16,384 Colors (Blink)
    Backlight
    White LED (User nonreplaceable parts. When replacement is required, contact your local distributor.)
    Brightness Control
    8 Levels (Adjusted with the touch panel or the software)
    Backlight Service Life
    50,000 hrs. or more (continuous operation at 25°C [77 °F] before backlight brightness decreases to 50%)
    Language Fonts
    Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters) ANK: 158 (Korean fonts, Simplified Chinese and Traditional Chinese fonts are downloadable.)
    Character Sizes
    Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts
    Font Sizes
    Standard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times. *1
    8 x 16 dots
    80 char. x 30 rows
    16 x 16 dots
    40 char. x 30 rows
    32 x 32 dots
    20 char. x 15 rows
    8 x 8 dots
    80 char. x 60 rows
    Program Area
    FLASH EPROM 132 KB (Equivalent to 15,000 steps) *2
    Variable Area
    None
    Application Memory
    FLASH EPROM 16 MB (including a logic program area)
    Data Backup
    SRAM 128 KB (Replaceable Lithium battery for backup memory)
    Clock Accuracy
    ±65 sec/month (deviation at room temperature and power is OFF) *3
    Touch Panel Type
    Resistive Film (analog)
    Touch Panel Resolution
    1,024 x 1,024
    Touch Panel Service Life
    1,000,000 times or more
    Serial (COM1)
    RS-232C Asynchronous Transmission Data Length: 7 or 8 bits, Parity: none, Odd or Even, Stop Bit: 1 or 2 bits, Data Transmission Speed: 2,400 bps to 115.2 kbps, Connector: D-Sub9 (plug)
    Serial (COM2)
    RS-422/485 Asynchronous Transmission Data Length: 7 or 8 bits, Parity: none, Odd or Even Stop Bit: 1 or 2 bits, Data Transmission Speed: 2,400 bps to 115.2 kbps, 187.5kbps (MPI) Connector: D-Sub9 (plug)
    Ethernet (LAN)
    IEEE802.3i/IEEE802.3u, 10BASE-T/100BASE-TX Connector: Modular jack (RJ-45) x 1
    USB (TYPE-A)
    Conforms to USB2.0 (TYPE-A) x 1, Power Supply Voltage: DC 5 V ±5 %, Output Current: 500 mA or less, Communication Distance: 5 m [16.4ft.] or less
    USB (mini-B)
    Conforms to USB2.0 (mini-B) x 1, Communication Distance: 5 m [16.4ft.] or less
    SD Card
    SD Card Slot x 1

    1Other font sizes can be set up with the Editor software.

    2Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB.

    3Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec/month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.

     

    General Specifications

    International Safety Standards
    Rated Input Voltage
    DC 24V
    Input Voltage Limits
    DC 19.2 to 28.8V
    Allowable Voltage Drop
    10 ms or less
    Power Consumption
    17 W or less
    In-Rush Current
    30 A or less
    Voltage Endurance
    AC 1,000 V 20 mA for 1 min (between charging and FG terminals)
    Insulation Resistance
    DC 500 V, 10 MΩ or more (between charging and FG terminals)
    Surrounding Air Temperature
    0 to 50 °C (32 to 122 °F)
    Storage Temperature
    -20 to 60 °C (-4 to 140 °F)
    Ambient Humidity
    10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] or less - no condensation.)
    Storage Humidity
    10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] or less - no condensation.)
    Dust
    0.1 mg/m³ (10⁻⁷ oz/ft³) or less (non-conductive levels)
    Pollution Degree
    For use in Pollution Degree 2 environment
    Atmosphere
    Free of corrosive gases
    Air Pressure (altitude range)
    800 to 1,114 hPa (2,000 m [6,561ft.] above sea level or less)
    Vibration Resistance
    IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration: 9.8 m/s², X, Y, Z directions for 10 cycles (approx. 100 min)
    Concussion Resistance
    IEC/EN61131-2 compliant 147 m/s², X, Y, Z directions for 3 times
    Noise Immunity
    Noise Voltage: 1,000 Vp-p, Pulse Duration: 1 µs, Rise Time: 1 ns (via noise simulator)
    Electrostatic Discharge Immunity
    Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3)
    Grounding
    Functional grounding: Grounding resistance of 100Ω, 2mm² (AWG 14) or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
    Structure
    IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure) *4
    Cooling Method
    Natural air circulation
    Weight Approx.
    2.5 kg [5.5 lb] or less (display unit only)
    External Dimensions
    W315x H241x D56 mm [W12.4 x H9.49 x D2.2 in.]
    Panel Cut Dimensions
    W301.5 x H227.5 mm [W11.87 x H8.96 in.], Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.] *5

    4The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit's level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the GP unit, be sure to confirm the type of conditions that will be present in the GP's operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.

    5Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the "Panel Cut Dimensions", depending on wall's material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.

     

    External Dimensions

    GP4000 Series External Dimensions

    Panel Cut-out

    GP4000 Series Panel Cutout

    External Dimensions with cables